Blog

18 Sept 2026
Why is my split AC flap (louver) not moving?
A failed swing motor — the small 12V DC stepper motor that turns the flap — is a common cause. Rule out the simple…

18 Sept 2026
How to find the right AC swing motor part number (24BYJ48, MP24GA5, MP35EA…)
Read it off the old motor. The number printed on it — 24BYJ48, MP24GA5, MP28VB, MP35EA, 20BYJ46, 30BYJ46 or 35BYJ46 —…

18 Sept 2026
Brand-wise AC swing motor guide: LG, Samsung, Voltas, Daikin and more
Use the brand to narrow it down and the number on your old motor to decide. Part numbers seen in Indian spare-part…

18 Sept 2026
What does an AC swing motor cost in Ahmedabad?
₹200 at Shreeji Refrigeration in Chandkheda, Ahmedabad — the same price whichever brand you choose. What decides the…

18 Sept 2026
What is a dummy AC indoor unit, and when is it used?
An empty split AC indoor unit body — the front panel/cover and chassis only, with no cooling coil, blower, motor, PCB…